FLUKE-376 (½ÅÁ¦Ç°)

* ÃÖ½ÅÀÇ Á¢¼ÓÀåÄ¡ÀÎ iFlex Ç÷º½Ãºí Àü·ù ÇÁ·Îºê¸¦ ÀÌ¿ëÇÏ¿© Å« Äܵ§¼­³ª ¹ÐÁýµÈ µµ¼±µéÀÌ ÀÖ´Â ºÐÀü¹ÝÀÇ Àü·ù ÃøÁ¤°¡´É
* 500 Hz ÁÖÆļö, 60 k¥Ø ÀúÇ×ÃøÁ¤ °¡´É
* 1,000 uF ijÆнÃÅϽº ÃøÁ¤ °¡´É
* ¾ÈÀüµî±Þ CAT IV 600 V, CAT III 1,000 V

- True-rms AC/DC 1000A Àü·ù ÃøÁ¤ (Á¤È®µµ 2%¡¾5 digits)

- True-rms AC 2500A Àü·ù ÃøÁ¤ (iFlex flexible current probe ÀÌ¿ë½Ã, Á¤È®µµ 3%¡¾5 digits)

- True-rms AC 1000V Àü¾Ð ÃøÁ¤ (Á¤È®µµ 1.5%¡¾5 digits)

- True-rms DC 1000V Àü¾Ð ÃøÁ¤ (Á¤È®µµ 1.0%¡¾5 digits)

- 500Hz ÁÖÆļö & 60k¥Ø ÀúÇ× ÃøÁ¤ °¡´É

- 1000uF ijÆнÃÅϽº ÃøÁ¤ °¡´É

- ¾ÈÀüµî±Þ CAT IV 600V, CAT III 1000V

 

 FLUKE-376

 ÀüµµÃ¼ ÃøÁ¤ ±¸°æ

 ÃÖ´ë 34 mm 

 »ç¿ëȯ°æ¿Âµµ

 - 10 ~  50¨¬C

 º¸°üȯ°æ¿Âµµ

 - 40 ~  60¨¬C

 »ç¿ëȯ°æ½Àµµ

 < 90% @ 10 to 30 ¨¬C, < 75% @ 30 to 40¨¬C

 »ç¿ëȯ°æ±â¾Ð

 0 to 3000 m

 Å©±â

 246 x 83 x 43 mm, (9.685 x 3.267 x 1.692 in.)

 ¹«°Ô

 388G, (14 oz.) 

 Temperature Coefficient

 0.01% ¨¬C (<18¡É or > 28¡É)