02
Źµµ°è HI88703
* Á¤È®ÇÑ ÃøÁ¤°ú ¿À·£±â°£ÀÇ ¾ÈÁ¤¼ºÀ» º¸Àå
* ºûÀÌ ºø³ª°¡°Å³ª »öÀÌ ¹æÇع޴ °ÍÀ» ÃÖ¼ÒÈÇÏ´Â ÃÖ÷´Ü ±â¼úÀÇ ±¤ÇÐ ½Ã½ºÅÛ »ç¿ë
* ÀÚÁÖ º¸Á¤À» ¿äÇÏÁö ¾Êµµ·Ï ·¥ÇÁÀÇ °µµ º¯È¿¡ ´ëÇØ º¸»ó
* Ưº°ÇÑ ±¤ÇÐ À¯¸®·Î ¸¸µé¾îÁø 25 mm Å¥ºªÀº ÃøÁ¤ÀÇ ½Å·Ú¼º°ú ÀÏ°ü¼º º¸Àå
* EPA ÄÄÇöóÀ̾𽺠±â·Ï¸ðµå
* EBC ¿Í Nephelos ÃøÁ¤´ÜÀ§ ÀÌ¿ë °¡´É
* ÃøÁ¤µÈ »ùÇðú ÇÊ¿ä Á¤È®µµ¿¡ µû¶ó Á¤±Ô ÃøÁ¤ (normal), Áö¼ÓÃøÁ¤(continuous), ½ÅÈ£ Æò±ÕÃøÁ¤ (signal averaging) Áß ¼±Åà °¡´É
* º¸Á¤»óŸ¦ ÃßÀûÇÒ ¼ö ÀÖ´Â G.L.P. (Good Laboratory Practice) ±â´É
* ¸¶Áö¸· º¸Á¤Æ÷ÀÎÆ®, ½Ã°£, ³¯Â¥¸¦ È®ÀÎ °¡´É
* ÀÌÇØÇϱ⠽±µµ·Ï Æí¸®ÇÑ ÀÎÅÍÆäÀ̽º¿Í ±×·¡ÇÈ LCD »ç¿ë
* °£´ÜÇÏ°Ô Å°¸¦ ´·¯ µµ¿ò¸» ÀÌ¿ë
* ¿©·¯ ¾ð¾î Áö¿ø
* ±â°è ÀÛµ¿½Ã È®Àΰú ¿¡·¯¸¦ ¼Ò¸®·Î ¾Ë¸²
* ¼³¸í¸ðµå´Â ºÐ¼®°úÁ¤À» »ç¿ëÀÚ¿¡°Ô ¼¼¼¼È÷ ¾È³»
* °ø±ÞµÈ Ç¥ÁØ¿ë¾× (< 0.1, 15, 100, 750, 2000 NTU) À» »ç¿ëÇÏ¿© 2, 3, 4Æ÷ÀÎÆ®º¸Á¤À» ½ÇÇà °¡´É
* Ç¥Áؾ×À» ÁغñÇÑ´Ù¸é º¸Á¤Æ÷ÀÎÆ® ¼öÁ¤ °¡´É
* ·Î¡±â´ÉÀº ÃøÁ¤¿¡ ´ëÇÑ ¸ðµç Á¤º¸ Á¦°ø
* ³»ºÎ ¸Þ¸ð¸®¿¡ 200 °³±îÁö ÀúÀå °¡´É
* ´õ ¸¹Àº ºÐ¼®°ú ÀúÀåÀ» À§ÇØ USB Æ÷Æ®¸¦ »ç¿ëÇÏ¿© PC ·Î ´Ù¿î·Îµå °¡´É
¢º Á¦Ç° Ư¡
- ³·Àº Źµµ¿¡ ½Å·ÚµµÀÖ°í Á¤È®ÇÑ ±â·ÏÀ» Á¦°øÇϱâÀ§ÇÑ ¼öÁúºÐ¼®À» À§ÇØ ¸¸µé¾îÁ³½À´Ï´Ù.
- USEP¿Í Standard MethodsÀÇ ÇÊ¿ä¿ä°ÇÀ» ¸¸Á·½ÃÅ°°í ´É°¡ÇÕ´Ï´Ù.
ratiometricÃøÁ¤ÀÌ »ç¿ëµÇ¸é 0.00¿¡¼ 4000 NTU (Nephelometric Turbidity Units) ¹üÀ§¿¡¼ °¡´ÉÇϸç
non ratio method°¡ »ç¿ëµÇ¸é 0.00 ¿¡¼ 40.0 NTU ¹üÀ§¿¡¼ ÃøÁ¤°¡´ÉÇÕ´Ï´Ù.
¢º Á¦Ç° »ç¾ç
ÃøÁ¤¹üÀ§ - non ratio mode |
0.00 to 9.99; 10.0 to 40.0 NTU 0.0 to 99.9; 100 to 268 Nephelos 0.00 to 9.80 EBC |
ÃÖ¼ÒÃøÁ¤´ÜÀ§- non ratio mode |
0.01; 0.1 NTU 0.1; 1 Nephelos 0.01 EBC |
ÃøÁ¤¹üÀ§ - ratio mode |
0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU 0.0 to 99.9; 100 to 26800 Nephelos 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC |
ÃÖ¼ÒÃøÁ¤´ÜÀ§- ratio mode |
0.01; 0.1; 1 NTU 0.1; 1 Nephelos 0.01; 0.1, 1 EBC |
ÃøÁ¤ ¼±Åà |
Automatically |
Á¤È®µµ |
¡¾2% of reading plus 0.02 NTU (0.15 Nephelos; 0.01 EBC) ¡¾5% of reading above 1000 NTU (6700 Nephelos; 245 EBC) |
À翬¼º |
¡¾1% of reading or 0.02 NTU (0.15 Nephelos; 0.01 EBC) whichever is greater |
Stray Light |
< 0.02 NTU (0.15 Nephelos; 0.01 EBC) |
ºû ŽÁö |
Silicon Photocell |
¹æ¹ý |
Nephelometric method (90¡Æ) or Ratio Nephelometric Method (90¡Æ & 180¡Æ), Adaptation of the USEPA Method 108.1 and Standard Method 2130 B. |
ÃøÁ¤¸ðµå |
Normal, Average, Continuous |
ŹµµÇ¥ÁØ |
<0.1, 15, 100, 750 and 2000 NTU |
º¸Á¤ |
Two, three, four or five-point calibration |
Light Source |
Tungsten filament lamp |
·¥ÇÁ¼ö¸í |
Greater than 100,000 readings |
¾×Á¤ |
40 x 70mm graphic LCD (64x128 pixels) with backlight |
LOG ¸Þ¸ð¸® |
200 records |
Serial Interface |
USB |
ȯ°æ |
0¡ÆC to 50¡ÆC; max 95% RH non-condensing |
Àü¿ø°ø±Þ |
230 V/50 Hz or 115 V/60 Hz 20 W |
ÀÚµ¿²¨Áü |
After 15 minutes of non-use |
±Ô°Ý / ¹«°Ô |
230(L) x 200(W) x 145(H)mm / 2.5kg |
¿É¼Ç |
Ç¥ÁØ¿ë¾×(<0.1, 15, 100, 750 and 2000 NTU)À» »ç¿ëÇÏ¿© 2,3,4Æ÷ÀÎÆ®º¸Á¤À» ½ÇÇà |
Solution | |
HI 88703-11 |
Calibration set for turbidimeter |
HI 93703-50 |
Solution for Turbidity Calibration |
Accessories | |
HI 93703-58 |
Silicon oil (15 mL) |
H 731318 |
Tissue for Wiping Cuvets |
HI 731331 |
Glass Cuvet for HI 957xx Series Meters |
HI 731335N |
Caps for cuvets |
HI 92000 |
Windows¢ç Compatible Software for Logging Instruments, Photometers and Turbidity Meters |
Solution
| ||
HI 88703-11 |
| | Calibration set for turbidimeter |
HI 93703-50 |
| | Solution for Turbidity Calibration |
Accessories | ||
HI 93703-58 |
| | Silicon oil (15 mL) |
H 731318 |
| | Tissue for Wiping Cuvets |
HI 731331 |
| | Glass Cuvet for HI 957xx Series Meters |
HI 731335N |
| | Caps for cuvets |
HI 92000 |
Windows¢ç Compatible Software for |