Àüµµµµ HI2300

* Ź»ó¿ë Àüµµµµ ±â±â
* Àüµµµµ, TDS, NaCl, ¿Âµµ ÃøÁ¤
* ÀÚµ¿ÃøÁ¤¹üÀ§ ±â´É : EC ¿Í TDS ÀÇ °¡Àå Á¤È®ÇÑ ºÐ¼® ¹üÀ§¸¦ ±â±â°¡ ÀÚµ¿À¸·Î ¼³Á¤
* ÃøÁ¤°ªÀº ÀÚµ¿Àû (ATC) À¸·Î³ª ¼öµ¿Àû (MTC) À¸·Î ¿Âµµ¸¦ À§ÇØ º¸»ó
* ¿Âµµº¸»ó °ª°ú ¿Âµµ°è¼ö °ªÀº ÇÊ¿ä¿¡ µû¶ó »ç¿ëÀÚ°¡ ¼±Åà °¡´É
* ¿Âµµº¸Á¤ ±â´ÉÀ» ÇØÁ¦ÇÏ°í ½ÇÁ¦ Àüµµµµ ÃøÁ¤ °¡´É
* ¾ÈÁ¤ÇÑ Áö½Ã±â, GLP ±â´É, USB Connector ¸¦ ÅëÇØ PC ·Î µ¥ÀÌÅÍ Àü¼Û
* ID ÄÚµå È®ÀÎÀ» ÅëÇØ »ç¿ëÀÚ°¡ ±â±â »ç¿ë
* 6 °³ÀÇ ´Ù¸¥ Àüµµµµ ÃøÁ¤¹üÀ§ : 00.0 ~ 29.99 µS/cm, 30.0 ~ 299.9 µS/cm, 300 ~ 2999 µS/cm, 3.00 ~ 29.99 mS/cm, 30.0 ~ 200.0 mS/cm. ½ÇÁ¦ Àüµµµµ 500.0 mS/cm ±îÁö
* ¿Âµµ º¸Á¤°ªÀº 0¡ÆC ¶Ç´Â 50¡ÆC ¿¡¼­ ¼³Á¤ °¡´É
* ¿Âµµ°è¼ö´Â 0.00 ~ 6.00 % ±îÁö »ç¿ëÀÚ°¡ ¼±ÅÃ
* TDS ´Â 0.40 ¿¡¼­ 0.80 ±îÁö Á¶Àý °¡´É (ÃʱⰪ 0.50)
* TDS ÃøÁ¤¹üÀ§ : 1.50 ~ 14.99 ppt, 15.0 ~ 100.0 ppt, ½ÇÁ¦ TDS 400.0 g/L ±îÁö. TDS (with 0.80 factor)

¢º Á¦Ç° »ç¾ç

 

 HI 2300

 

 EC

 TDS

 NaCl

 Temperature

 (ÀÚµ¿ÃøÁ¤¹üÀ§)

 (ÀÚµ¿ÃøÁ¤¹üÀ§) 

 ÃøÁ¤¹üÀ§

 0.00 to 29.99 µS/cm

 0.00 to 14.99 ppm

 0.0 to 400.0 %

 -9.9 to 120.0¡ÆC

 30.0 to 299.9 µS/cm

 15.0 to 149.9 ppm

 300 to 2999 µS/cm

 150 to 1499 ppm

 3.00 to 29.99 mS/cm

 1.50 to 14.99 g/L

 30.0 to 200.0 mS/cm

 15.0 to 100.0 g/L

 Up to 500.0 mS/cm actual (*)  Conductivity

 Up to 400.0 g/L actual (*) TDS

 (with 0.80 factor)

 ÃÖ¼ÒÃøÁ¤´ÜÀ§

 0.01 S/cm (from 0.00 to 29.99

 S/cm)

 0.01 ppm (from 0.00 to 14.99 ppm)

 0.10%

 0.1¡ÆC

 0.1 S/cm (from 30.0 to 299.9

 S/cm)

 0.1 ppm (from 15.0 to 149.9 ppm)

 1 S/cm (from 300 to 2999

 S/cm)

 1 ppm (from 150 to 1499 ppm)

 0.01 mS/cm

(from 3.00 to 29.99mS/cm)

 0.01 g/L (from 1.50 to 14.99 g/L)

 0.1 mS/cm (over 30.0 mS/cm)

 0.1 g/L (over 15.0 g/L)

 Á¤È®µµ (@ 20¡ÆC)

 ¡¾ 1% of reading

 ¡¾ (0.05 µS/cm or 1 digit)

 ¡¾ 1% of reading

 ¡¾ (0.03 ppm or 1 digit)

 ¡¾ 1% of reading

 ¡¾ 0.4¡ÆC

 º¸Á¤

 1 point with 6 memorized buffers:

 84, 1413 ,5000,12880, 80000 or

 111800 µS/cm

¡¡

 1 point

 with HI 7037

 buffer (º°µµÆǸÅ)

 2 points

 at 0 and 50¡ÆC 

(plus ¡¾ 1¡ÆC adjustment)

 ¿Âµµ º¸Á¤

 0 ¿¡¼­ 60¡ÆC (ÀÚµ¿º¸Á¤ ¹× ¼öµ¿º¸Á¤)

 ¿Âµµ °è¼ö

 0.00 to 6.00 %/¡ÆC (for EC and TDS only) Default value is 1.90%/¡ÆC

 TDS ¿ä¼Ò

 0.40 to 0.80 (default value is 0.50)

 ÇÁ·Îºê

 HI 76310 Platinum 4-ring probe, K=1 nominal and built-in temperature sensor (included)

 GLP

 Storing of last calibration data

 Serial Interface

 RS232 - downloading of last calibration data

 Power Supply

 12 VDC adapter (included)

 Auto Off

 After 5 minutes (can be disabled)

 Casing

 IP 67

 È¯°æ

 0 to 50¡ÆC; 95% RH non-condensing

 ±Ô°Ý

 240 x 182 x 74 mm

 ¹«°Ô

 1.1 Kg

  (*) ½ÇÁ¦ Àüµµµµ´Â(or TDS) ¿ë¾×ÀÇ Àüµµµµ(¶Ç´Â TDS)°¡ º¸Á¤µÇÁö ¾ÊÀº°ÍÀÔ´Ï´Ù.

 

 

¢º ±âº» ±¸¼º

HI 2300-02 (230V) are supplied with HI 76310 conductivity probe, 12 Vdc power adapter and instruction manual.

HI 76310 4-ring Pt sensor EC probe with built-in temperature sensor and 1 m (3.3¡¯) cable